PRA number
2001/4753
Published date
Product description
Campaign No. PI 10054
Date range October 1966 through to 1999. Note: identical to Campaign No. PI 10055 in content, however the serial number range is entirely different.
Date range October 1966 through to 1999. Note: identical to Campaign No. PI 10055 in content, however the serial number range is entirely different.
Reasons the product is recalled
The pilot control valve in the hydrostatic transmission may be sensitive to oil contamination and oil temperature.
What consumers should do
Pilot valves need to be replaced with new valves. In addition, new steering control software, harness and sensors need to be installed to turn off the pilot control supply pressure and apply the brakes in the event of a pilot control valve sticking.
Supplier
Caterpillar of Australia Limited
Where the product was sold
Nationally
Responsible regulator
Australian Competition and Consumer Commission is the responsible regulator for this recall.