Mirabella—Electrical Portable Outlet Device

What are the defects?

Model FS06B: In addition to the 6 socket outlets, this product has two telephone connector sockets, which are intended to provide surge suppression to the telephone line. It is possible for the creepage and clearance distance between L.V. and components in the phone filter circuit to be less than the 8mm specified in AS/NZS3100 Table 4.1. Model FS06C: This product is silver in colour, and three of the six socket outlets are wider spaced to facilitate transformers with integral pins being plugged into those socket outlets. This product is fitted with a 3m long flexible supply cord. The product is not fitted with a switch at a maximum of 1.8m from the device as required by Clause 4.5.4(A) of AS/NZS3105.

Supplier
Mirabella
Where the product was sold
Nationally

Responsible regulator

Australian Competition and Consumer Commission is the responsible regulator for this recall.

Australian Competition and Consumer Commission
Product category