Mitsubishi Motors Australia Ltd — 13-15.5MY XB ASX and 13-16MY ZJ & ZK Outlander
What are the defects?
All vehicles are subject to condition a) whilst only some vehicles are subject to condition b)
a) Improper sealing of parking brake caliper may allow water entry, causing rust on the parking brake shaft. As a result the brake shaft may stick, and this may allow the vehicle to roll away when parked;
b) A defect with the parking brake automatic adjuster may fail to compensate for brake pad wear, and this may allow the vehicle to roll away when parked.
What are the hazards?
These conditions may cause injury or an accident.
What should consumers do?
Mitsubishi Motors Australia will contact all known owners by mail and advise them to present their vehicle to their preferred dealer to rectify the defects.
Consumers who require further information can contact Mitsubishi Motors Australia on 1300 1312 11 or their preferred Dealer. To find a Mitsubishi dealer, visit https://www.mitsubishi-motors.com.au/customer-assistance/locate-a-servic...
Mitsubishi Motors Australia and Authorised Dealers
- 23 August 2012 - 20 May 2016
Responsible regulator
Department of Infrastructure, Transport, Regional Development and Communications is the responsible regulator for this recall.