Nitto Kohki—Hydraulic Pump

Identifying features

Model numbers HPD-05 can be found on the face plate attached to the slanted part of the HPD-05 Pump's blue cover.

What are the defects?

HPD-05 Pumps incorporating a certain PC Board can cause the HPD-05 Pump and associated punch to activate unintentionally.

The automatic and unintentional activation of the punch can be caused by the following chain of events: if the "Auto-Return/Inching" switch on the HPD-05 Pump is set to the "Auto Return" position and the main power source switch on the HPD-05 Pump is turned off for between approximately 5 to 11 seconds and then the power source switch on the HPD-05 Pump in turned on again.

Under these conditions, and possibly others, the HPD-05 Pump and punch unit will automatically activate without any activation of the switch on the punch unit.

The HPD-05 Pump and punch unit will not be automatically activated if the main power source on the HPD-05 Pump is turned off for approximately less than 5 seconds or approximately more than 11 seconds and then the power source switch on the HPD-05 Pump is turned on again.

What are the hazards?

Injury

What should consumers do?

Stop using the HPD-05 Pumps and contact Nitto Kohki at 07 3340 4600 between 8am and 5pm Monday to Friday to schedule a free PC Board retrofit to be carried out by an authorised electrical repairer.

Supplier
Nitto Kohki Australia Pty Ltd
Where the product was sold
Nationally

Responsible regulator

Australian Competition and Consumer Commission is the responsible regulator for this recall.

Australian Competition and Consumer Commission