Scania Australia—Scania K-series bus

Identifying features

Chassis numbers:
3598061, 3598064, 3598468, 3598465, 3598466, 3598467, 3598821, 3598822, 3598823, 3598824, 3601529, 3601542, 3601966, 3598081, 3601528, 3601543, 3601544, 3599403, 3599795, 3599796, 3599797, 3601967, 3601968, 3601969, 3601970, 3603038, 3603041, 3603044, 3603047, 3603050, 3603053, 3602477, 3602479, 3602481, 3602483, 3602485, 3607031, 3606036, 3601971, 3605491, 3604657, 3604660, 3604663, 3574643, 3573780, 3579129, 3579150, 3579139, 3588146, 3588159, 3588192, 3589729, 3592388, 3592390, 3592392, 3592383, 3592384, 3592385, 3592884, 3592887, 3592889, 3592882, 3592881, 3592883, 3588552, 3588565, 3588574, 3588525, 3592954, 3588539, 3593279, 3592391, 3592393, 3592387, 3592386, 3592389, 3592885, 3592953, 3592949, 3593278, 3593275, 3593276, 3593280, 3593984, 3593970, 3593977, 3593978, 3593980, 3594500, 3594501, 3594492, 3594494, 3594497, 3594801, 3594812, 3595230, 3595231, 3595232, 3595233, 3595234, 3595235, 3595236, 3594498, 3594499, 3595638, 3595611, 3592952, 3592950, 3592951, 3593277, 3594496, 3594502, 3592886, 3592888, 3592907, 3592908, 3592906, 3593281, 3593979, 3593981, 3593982, 3593983, 3594493, 3594495, 3596129, 3596134, 3596137, 3596140, 3596144, 3596149, 3596488, 3596492, 3596493, 3596494, 3596495, 3596815, 3596816, 3596817, 3597690, 3597691, 3597692, 3597705, 3597230, 3597706.

What are the defects?

There have been instances where the bellows brackets have fractured. The bellows brackets fracture at the upper torque rod attachment. This is because the suspension brackets side wall is approx. 10 mm narrower than specified dimension.

What are the hazards?

If the bracket was to completely fail it can intrude into the wheel well and the impact can injure passengers inside the bus.

What should consumers do?

It is important that you contact your Scania Dealer /Scania Branch to make an appointment to have the above campaign carried out. This will allow them to order parts in advance that are required for your vehicle. All work carried out (parts and labour) related to this recall will be at no cost to you.

We appreciate your prompt attention to this matter.

Supplier
Scania Australia
Traders who sold this product

Scania Australia

Where the product was sold
New South Wales
Queensland

Recall advertisements and supporting documentation

Responsible regulator

Department of Infrastructure, Transport, Regional Development and Communications is the responsible regulator for this recall.

Department of Infrastructure, Transport, Regional Development and Communications
Product category