Stauff Corporation Pty Ltd—Stauff Hydraulic Fitting Test Point model SMK20JIC9/16"

Identifying features

Only fittings sold in Zinc Nickel plated finish since 1st. March 2008 are affected.
Zinc Nickel surface finish has a grey appearance.

Prior to March 2008 these parts were supplied in surface finish (A3C) which has a yellow colour and is not affected by this recall.

What are the defects?

This part features a nut restrained by a wire nail.

A defective swivel nut has been used where the groove for the wire nail is too large and could lead to a situation where the test point body can not be properly held under pressure.

What are the hazards?

A possibilty exists that the test point body could leak or, in some cases be expelled from the fitting creating an impact hazard to persons and property.

What should consumers do?

Immediately cease use of the part.

Remove the part from service and return it to point of sale for free replacement.

Traders who sold this product

Stauff Corporation Pty Ltd

Where the product was sold
Nationally

Responsible regulator

Australian Competition and Consumer Commission is the responsible regulator for this recall.

Australian Competition and Consumer Commission
Product category