Product description
Caravan Gas Cookers
See a list of details to help identify the product
Reason the product is recalled
The caravan gas cooker has not been installed with adequate support in the cavity in accordance with AS/NZS5601 in order to prevent movement.
The hazards to consumers
Excess movement or vibration may cause the cookers fitting lines to leak, posing a potential risk of explosion or fire.
What consumers should do
1. Contact a licensed gas fitter to check that the base of your cooker has been supported and or the top is braced to prevent flexing. In particular check below the cooker to ensure the base of the oven is resting on a shelf and is not hanging freely.
2. If you find that the cooker is not supported as per the installation instructions and requirements of AS/NZS 5601 you must contact the caravan manufacturer to have this rectified and the appliance must be checked by a licensed gas fitter for any damage and leaks. In particular the licensed gasfitter must confirm the installation mounting is adequate and undamaged, there is no damage to the appliance and the pipes from the interlock valve, to the oven burner and the grill burner have no signs of damage or fatigue. Fitting a gas leak detector below the appliance is also recommended.
3. If you are unsure of how to assess the installation or you are unable to contact a caravan manufacturer because it has ceased trading contact Swift for further advice on 03 93593068 or by email accounts@swiftappliancegroup.com.au
2. If you find that the cooker is not supported as per the installation instructions and requirements of AS/NZS 5601 you must contact the caravan manufacturer to have this rectified and the appliance must be checked by a licensed gas fitter for any damage and leaks. In particular the licensed gasfitter must confirm the installation mounting is adequate and undamaged, there is no damage to the appliance and the pipes from the interlock valve, to the oven burner and the grill burner have no signs of damage or fatigue. Fitting a gas leak detector below the appliance is also recommended.
3. If you are unsure of how to assess the installation or you are unable to contact a caravan manufacturer because it has ceased trading contact Swift for further advice on 03 93593068 or by email accounts@swiftappliancegroup.com.au
Details to help identify the product
Supplier running the recall
Who sold the product
Various caravan manufacturers
Identifying product features
All cookers up to 5 years old by date of caravan purchase. (Cookers are required to be regularly serviced but must be checked by Swift after five years).
Identifying numbers
Other identifying numbers
All cookers up to 5 years old by date of caravan purchase. (Cookers are required to be regularly serviced but must be checked by Swift after five years).
Where the product was sold
Nationally
Responsible regulators
Regulators are established or appointed by government. They enforce regulations and rules.
Quote PRA number 2015/14707 when contacting a regulator about this recall.
Recall and remedy questions
Contact the Australian Competition and Consumer Commission if you have:
- a question about the remedy being offered to you by the business that is responsible for managing this recall, or
- concerns about the way the business is managing this recall.
Product questions
Speak to Energy Safe Victoria if you have a question about the reason the product is recalled or the hazards to consumers.