Orford Refrigeration—Hot Box Oven

PRA number

2007/9513

Published date

Product description

Model years from 15 October 1997 to 11 May 2007.
Identifying features
Model no. HCM96GN. Serial No. 01013589 - 12990894.

Other identifying numbers

Model no. HCM96GN. Serial No. 01013589 - 12990894.

Reasons the product is recalled

The ovens have been manufactured with incorrect wiring in the electrical panel. They have been wired with no thermal protection on the heating elements. The circuit needs to be modified so that the safety thermostat is in the same circuit as the heating elements. Under size 7.5 amp wire has been used to supply power to the relay contact. This needs to be upgraded to the correct 15 amp wire.

The hazards to consumers

Electrical fire.

What consumers should do

Orford will contact all customers who purchased the ovens and send an agent to the consumer's premises to repair/modify the defective ovens at no cost to the customer.

Supplier

Orford Refrigeration Pty Ltd

Where the product was sold

New South Wales
Queensland

Responsible regulator

Australian Competition and Consumer Commission is the responsible regulator for this recall.