Product description

Threading Machines—RIDGID 300 Power Drive, RIDGID 535 M/C, RIDGID 300 & 1233 threading machines.

See a list of details to help identify the product

Reason the product is recalled

Ridge Tool Australia recently determined that the setscrews that retain the brush holders in these motors may not be properly tightened. This could allow the brush holder to back out and the brush lead to contact the motor housing. If a machine in this condition is used with an improperly grounded power supply, this could result in an electrical shock or fire hazard which could cause serious injury or death.

The hazards to consumers

Electric shock and fire.

What consumers should do

Dealers should take immediate steps to determine if they have any of these products in their possession or if they have been sold. If they are still in their possession, do not sell or use them until they have been reworked. If they have been sold dealers must take immediate measures to contact the customer and advise them of the issue so that they can be reworked.
Contact Ridge Tool Technical Services at (03) 9930 7000 or sales.australia@ridgid.com for information on correcting this issue.

Details to help identify the product

Supplier running the recall

Who sold the product

Plumbing and Industrial Distributors

Identifying product features

Machines with serial numbers ending in 0408,0508,0608,0708,0808,0908,1008 or 1108

Identifying numbers

Other identifying numbers

Machines with serial numbers ending in 0408,0508,0608,0708,0808,0908,1008 or 1108

Where the product was sold

Nationally

Responsible regulators

Regulators are established or appointed by government. They enforce regulations and rules.

Quote PRA number 2009/10817 when contacting a regulator about this recall.

Recall and remedy questions

Contact the Australian Competition and Consumer Commission if you have:

  • a question about the remedy being offered to you by the business that is responsible for managing this recall, or
  • concerns about the way the business is managing this recall.